x
Send Your Inquiry Today
  • IFR26650-3600-WT 3.2V 3600mAh LiFePO4 cell horizontal
  • IFR26650-3600-WT 3.2V 3600mAh LiFePO4 cell upright
  • IFR26650-3600-WT 3.2V 3600mAh LiFePO4 cell horizontal
  • IFR26650-3600-WT 3.2V 3600mAh LiFePO4 cell upright

Wide-Temperature 26650 LiFePO4 Battery 3.2V 3600mAh (-40°C to +80°C)

-40°C to +80°C discharge range

SpecificationValue
ModelIFR26650-3600-WT
Nominal Voltage3.2 V
Nominal Capacity3,600 mAh
Minimum Capacity3,550 mAh
Standard Charging0.2C (720 mA) CC-CV
Max Continuous Discharge2.0C (7.2 A)
Peak Pulse DischargeUp to 5.0C (18.0 A)
Operating Temp (Charge)-20°C to +50°C
Operating Temp (Discharge)-40°C to +80°C
Dimensions26.2 ± 0.3 mm (Dia) × 65.5 ± 0.5 mm (H)

26650 LiFePO4 Cell for Wide-Temperature Systems

The IFR26650-3600-WT is a 3.2V, 3600mAh cylindrical wide-temperature LiFePO4 battery cell for outdoor telemetry, solar-powered trackers and industrial energy storage. Its specified discharge range is -40°C to +80°C; charging is specified from -20°C to +50°C.

Key Highlights

Core electrical, temperature and service-life specifications from the source document.

LiFePO4 cell chemistry
LiFePO4 Chemistry & Cycle Life

Lithium iron phosphate chemistry with at least 2,000 cycles at 25°C under stated conditions.

3.2V 3600mAh capacity and voltage
Nominal Capacity & Voltage

3.2V, 3,600mAh in the 26650 format.

Wide operating temperature
Operating Temperature

Charge: -20°C to +50°C; discharge: -40°C to +80°C.

High discharge performance
Discharge Performance

2C continuous; up to 5C for a 10-second pulse.

Smart BMS Protection

Custom pack designs can integrate overcharge, over-discharge, overcurrent and short-circuit protection, plus temperature sensing. Automatic low-temperature charge cutoff can be evaluated for the selected cell, charger, BMS and enclosure.

Smart BMS Protection for 26650 Wide-Temperature Battery
Safety and Transport Documentation Support

Safety & Transport Documentation

VTCBATT can support UN38.3 transport testing, MSDS/SDS and applicable RoHS documentation for the final product. IEC 62133-related and UL battery safety evaluations may be assessed according to the final cell or pack design and target market.

Performance Advantages

Why Choose the 26650 3600mAh Wide-Temp Cell?

Designed for outdoor systems exposed to severe cold, high heat and transmission-current peaks.

Extended sub-zero discharge
Extended Sub-Zero Discharge (-40°C)

The low-temperature electrolyte and cathode design support approximately 59.2% capacity retention at -40°C under the documented 0.5C discharge test.

Scorching heat stability
Scorching Heat Stability (+80°C)

The source test data reports 96.7% capacity retention at +80°C under 0.5C discharge for hot outdoor and enclosed installations.

3600mAh energy capacity
Class-Leading Energy Density (3,600mAh)

The 3,600mAh nominal capacity extends runtime in the standard 26650 cylindrical footprint for remote field equipment.

High-pulse transmission capability
High-Pulse Transmission Capability

Up to 5C pulse discharge for 10 seconds supports short transmission peaks in LPWAN, LTE-M, NB-IoT and telemetry hardware.

Get an Instant Quote
Target Applications

Target Applications

Wide-temperature energy for remote industrial equipment and telemetry systems.

Solar-powered asset and fleet tracker

Power for container, railcar, heavy-equipment and commercial-fleet trackers exposed to winter cold and desert heat.

Remote IoT and meteorological station

Off-grid power for weather monitoring, wildfire sensors, hydrological telemetry and high-altitude instruments.

Smart utility and pipeline telemetry
Smart Utility & Pipeline Telemetry

Long-term field power for substations, cathodic-protection monitors and oil or gas valve controls.

Offshore buoy and marine instrumentation
Offshore Buoys & Marine Instrumentation

Wide-temperature power for navigation aids, research buoys and coastal water-monitoring systems.

Test Data

Temperature Performance

Source test tables with reconstructed SVG voltage–capacity curves and operating-limit context

Low-Temperature Charging Voltage–Capacity Curves

Charge rate varies by test temperature.

Low-Temperature Charging Capacity Retention

Engineering Tip: For off-grid solar trackers and outdoor telemetry nodes, program the charge controller or BMS to reduce charge current below 0°C. Validate the final current limit with the selected cell, charger, enclosure and required service life.
Ambient TemperatureCharging Rate (C-rate)Average Charging CapacityCapacity Retention (%)Design Recommendation
25°C0.2C (720 mA)3,634 mAh100.0%Standard CC-CV charging
0°C0.2C (720 mA)3,558 mAh97.9%Full solar charging support
-10°C0.2C (720 mA)3,425 mAh94.2%Direct trickle / solar input
-20°C0.2C (720 mA)3,154 mAh86.8%Controlled sub-zero solar recharge
-30°C0.1C (360 mA)3,171 mAh87.2%Derated charging current via BMS
-45°C0.01C (36 mA)2,277 mAh62.6%Low-power trickle energy harvesting

The -45°C point is a test result outside the specified charging range.

Wide-Temperature Discharge Voltage–Capacity Curves

0.5C discharge rate.

Wide-Temperature Discharge Capacity Retention

Operating TempDischarge RateDelivered Capacity (0.5C)Capacity Retention RateTypical Field Use Case
+80°C0.5C~3,501 mAh96.7%Enclosed metal trackers under direct sunlight
+60°C0.5C~3,527 mAh97.4%Heavy equipment & engine compartment trackers
+45°C0.5C~3,539 mAh97.8%Middle East / Southern US summer deployment
+25°C0.5C~3,620 mAh100.0%Baseline laboratory rating
0°C0.5C~3,281 mAh90.6%Mild winter outdoor operation
-10°C0.5C~2,965 mAh81.9%Sub-zero cold climate telemetry
-20°C0.5C~2,580 mAh71.3%Winter fleet tracking & cold-chain monitoring
-30°C0.5C~2,600 mAh71.8%High-latitude winter asset deployment
-40°C0.5C~2,143 mAh59.2%Arctic/Nordic remote weather stations & GPS
-50°C0.5C~1,137 mAh31.4%Not specified

The -50°C point is a test result outside the specified discharge range.

Can this 26650 LiFePO4 cell be charged below 0°C?

The stated charging range is -20°C to +50°C. The source tests use 0.2C at 0°C to -20°C, then lower rates at colder test points. Program the charger or BMS to reduce current below 0°C and validate the final profile for the selected cell, pack and service-life target.

What capacity does it retain at -40°C?

The source table reports 59.2% capacity retention at -40°C under 0.5C discharge to the stated cutoff. Actual pack-level runtime also depends on enclosure heat transfer, wiring losses, BMS limits and load profile.

Does high-temperature operation at +80°C cause swelling or safety hazards?

+80°C is the upper discharge test and stated operating boundary in the source document, which reports 96.7% capacity retention at 0.5C. Pack safety and thermal behavior still depend on cell lot, enclosure, BMS and application conditions, so the final design should be validated at the intended duty cycle.

Do you support custom lead wires, connectors and casing?

Yes. Project options can include JST, Molex or Amphenol connectors, external NTC temperature sensing, custom wire gauges and ruggedized housings. Availability and ratings are confirmed after review of the pack voltage, current, environment and mechanical drawing.

IFR26650-3600-WT Technical Overview

This 3.2V 3600mAh 26650 lithium iron phosphate cell is specified for -40°C to +80°C discharge and -20°C to +50°C charging. The standard cylindrical cell measures 26.2 ± 0.3 mm in diameter and 65.5 ± 0.5 mm in height.

Technical Specifications

Specification ParameterValue / RatingTest Condition / Notes
ModelIFR26650-3600-WTCylindrical LiFePO4 Cell
Nominal Voltage3.2 VOperational voltage plateau
Nominal Capacity3,600 mAh0.2C discharge, 2.0V cut-off at 25°C
Minimum Capacity3,550 mAhStandard quality screening
Standard Charging0.2C (720 mA) CC-CV3.65V cut-off, 0.02C end current
Rapid Charging0.5C (1,800 mA)Supported under monitored BMS conditions
Max Continuous Discharge2.0C (7.2 A)Continuous current rating
Peak Pulse DischargeUp to 5.0C (18.0 A)10-second burst duration
AC Internal Resistance (1 kHz)Target: ≤25 mΩ (confirm by lot test)AC measurement at 1 kHz, 25°C, 50% SOC; final value depends on cell lot.
Discharge Cut-off Voltage2.0 VRecommended system setting
Operating Temp (Charge)-20°C to +50°CControlled charge current at sub-zero
Operating Temp (Discharge)-40°C to +80°CFactory low/high temp verified
Storage Temperature-20°C to +45°C50% State of Charge (SOC)
Dimensions26.2 ± 0.3 mm (Dia) × 65.5 ± 0.5 mm (H)Standard 26650 mechanical footprint
Cell WeightApprox. 88.0 ± 2.0 gSolid cylindrical construction

Charging Performance by Temperature

The source test table reports charging capacity at rates selected for each temperature. At -20°C and 0.2C, capacity retention is 86.8%. A separate -45°C test at 0.01C reports 62.6%; this test is outside the stated -20°C minimum operating charge temperature and requires engineering validation for any deployment.

Charging capacity retention by temperature

Ambient TemperatureCharging Rate (C-rate)Average Charging CapacityCapacity Retention (%)Design Recommendation
25°C0.2C (720 mA)3,634 mAh100.0%Standard CC-CV charging
0°C0.2C (720 mA)3,558 mAh97.9%Full solar charging support
-10°C0.2C (720 mA)3,425 mAh94.2%Direct trickle / solar input
-20°C0.2C (720 mA)3,154 mAh86.8%Controlled sub-zero solar recharge
-30°C0.1C (360 mA)3,171 mAh87.2%Derated charging current via BMS
-45°C0.01C (36 mA)2,277 mAh62.6%Low-power trickle energy harvesting

Discharge Performance by Temperature

At 0.5C discharge, the source table reports 59.2% retention at -40°C and 96.7% at +80°C. The -50°C data point is a test result outside the specified -40°C minimum discharge operating temperature.

Discharge capacity retention by temperature

Operating TempDischarge RateDelivered Capacity (0.5C)Capacity Retention RateTypical Field Use Case
+80°C0.5C~3,501 mAh96.7%Enclosed metal trackers under direct sunlight
+60°C0.5C~3,527 mAh97.4%Heavy equipment & engine compartment trackers
+45°C0.5C~3,539 mAh97.8%Middle East / Southern US summer deployment
+25°C0.5C~3,620 mAh100.0%Baseline laboratory rating
0°C0.5C~3,281 mAh90.6%Mild winter outdoor operation
-10°C0.5C~2,965 mAh81.9%Sub-zero cold climate telemetry
-20°C0.5C~2,580 mAh71.3%Winter fleet tracking & cold-chain monitoring
-30°C0.5C~2,600 mAh71.8%High-latitude winter asset deployment
-40°C0.5C~2,143 mAh59.2%Arctic/Nordic remote weather stations & GPS
-50°C0.5C~1,137 mAh31.4%Not specified

Custom Configurations

Available in 1S2P (3.2V 7.2Ah), 1S3P (3.2V 10.8Ah), 2S1P (6.4V 3.6Ah), 4S1P (12.8V 3.6Ah), and tailor-made pack layouts.

Custom 26650 LiFePO4 pack configurations

VTCBATT can evaluate the required series-parallel layout, BMS protection, temperature sensing, connector, wiring and enclosure for the final equipment design.

Request a Custom Configuration

Get an Instant Quote
       
contact

Send Your Inquiry Now

Looking for the perfect battery solution? Our expert engineering team is ready to support you from idea to delivery. Whether you need custom voltage, size, or application-specific design, we’re here to make it happen. Get in touch today and let us power your success—one battery at a time!
Get an Instant Quote

MEET VTCBATT

Meet VTCBATT at electronica 2026.

Bring your battery project to Munich. Meet our team to explore custom lithium and wide temperature battery solutions for your next device.

WHEN
November 10–13, 2026
WHERE
Messe München · Munich, Germany
BOOTH
Hall A5 · 171/2
Plan your visit

Let’s talk batteries. Let’s build what’s next.

Scroll to Top