Wide-Temperature 26650 LiFePO4 Battery 3.2V 3600mAh (-40°C to +80°C)
-40°C to +80°C discharge range
| Specification | Value |
|---|---|
| Model | IFR26650-3600-WT |
| Nominal Voltage | 3.2 V |
| Nominal Capacity | 3,600 mAh |
| Minimum Capacity | 3,550 mAh |
| Standard Charging | 0.2C (720 mA) CC-CV |
| Max Continuous Discharge | 2.0C (7.2 A) |
| Peak Pulse Discharge | Up to 5.0C (18.0 A) |
| Operating Temp (Charge) | -20°C to +50°C |
| Operating Temp (Discharge) | -40°C to +80°C |
| Dimensions | 26.2 ± 0.3 mm (Dia) × 65.5 ± 0.5 mm (H) |
26650 LiFePO4 Cell for Wide-Temperature Systems
The IFR26650-3600-WT is a 3.2V, 3600mAh cylindrical wide-temperature LiFePO4 battery cell for outdoor telemetry, solar-powered trackers and industrial energy storage. Its specified discharge range is -40°C to +80°C; charging is specified from -20°C to +50°C.
Key Highlights
Core electrical, temperature and service-life specifications from the source document.
Lithium iron phosphate chemistry with at least 2,000 cycles at 25°C under stated conditions.
3.2V, 3,600mAh in the 26650 format.
Charge: -20°C to +50°C; discharge: -40°C to +80°C.
2C continuous; up to 5C for a 10-second pulse.
Smart BMS Protection
Custom pack designs can integrate overcharge, over-discharge, overcurrent and short-circuit protection, plus temperature sensing. Automatic low-temperature charge cutoff can be evaluated for the selected cell, charger, BMS and enclosure.


Safety & Transport Documentation
VTCBATT can support UN38.3 transport testing, MSDS/SDS and applicable RoHS documentation for the final product. IEC 62133-related and UL battery safety evaluations may be assessed according to the final cell or pack design and target market.
Why Choose the 26650 3600mAh Wide-Temp Cell?
Designed for outdoor systems exposed to severe cold, high heat and transmission-current peaks.

The low-temperature electrolyte and cathode design support approximately 59.2% capacity retention at -40°C under the documented 0.5C discharge test.

The source test data reports 96.7% capacity retention at +80°C under 0.5C discharge for hot outdoor and enclosed installations.

The 3,600mAh nominal capacity extends runtime in the standard 26650 cylindrical footprint for remote field equipment.

Up to 5C pulse discharge for 10 seconds supports short transmission peaks in LPWAN, LTE-M, NB-IoT and telemetry hardware.
Target Applications
Wide-temperature energy for remote industrial equipment and telemetry systems.
Power for container, railcar, heavy-equipment and commercial-fleet trackers exposed to winter cold and desert heat.
Off-grid power for weather monitoring, wildfire sensors, hydrological telemetry and high-altitude instruments.

Long-term field power for substations, cathodic-protection monitors and oil or gas valve controls.

Wide-temperature power for navigation aids, research buoys and coastal water-monitoring systems.
Temperature Performance
Source test tables with reconstructed SVG voltage–capacity curves and operating-limit context
- Low-Temperature Charging Test
- Wide-Temperature Discharge Test
Low-Temperature Charging Voltage–Capacity Curves
Charge rate varies by test temperature.
| Ambient Temperature | Charging Rate (C-rate) | Average Charging Capacity | Capacity Retention (%) | Design Recommendation |
|---|---|---|---|---|
| 25°C | 0.2C (720 mA) | 3,634 mAh | 100.0% | Standard CC-CV charging |
| 0°C | 0.2C (720 mA) | 3,558 mAh | 97.9% | Full solar charging support |
| -10°C | 0.2C (720 mA) | 3,425 mAh | 94.2% | Direct trickle / solar input |
| -20°C | 0.2C (720 mA) | 3,154 mAh | 86.8% | Controlled sub-zero solar recharge |
| -30°C | 0.1C (360 mA) | 3,171 mAh | 87.2% | Derated charging current via BMS |
| -45°C | 0.01C (36 mA) | 2,277 mAh | 62.6% | Low-power trickle energy harvesting |
The -45°C point is a test result outside the specified charging range.
Wide-Temperature Discharge Voltage–Capacity Curves
0.5C discharge rate.
| Operating Temp | Discharge Rate | Delivered Capacity (0.5C) | Capacity Retention Rate | Typical Field Use Case |
|---|---|---|---|---|
| +80°C | 0.5C | ~3,501 mAh | 96.7% | Enclosed metal trackers under direct sunlight |
| +60°C | 0.5C | ~3,527 mAh | 97.4% | Heavy equipment & engine compartment trackers |
| +45°C | 0.5C | ~3,539 mAh | 97.8% | Middle East / Southern US summer deployment |
| +25°C | 0.5C | ~3,620 mAh | 100.0% | Baseline laboratory rating |
| 0°C | 0.5C | ~3,281 mAh | 90.6% | Mild winter outdoor operation |
| -10°C | 0.5C | ~2,965 mAh | 81.9% | Sub-zero cold climate telemetry |
| -20°C | 0.5C | ~2,580 mAh | 71.3% | Winter fleet tracking & cold-chain monitoring |
| -30°C | 0.5C | ~2,600 mAh | 71.8% | High-latitude winter asset deployment |
| -40°C | 0.5C | ~2,143 mAh | 59.2% | Arctic/Nordic remote weather stations & GPS |
| -50°C | 0.5C | ~1,137 mAh | 31.4% | Not specified |
The -50°C point is a test result outside the specified discharge range.
The stated charging range is -20°C to +50°C. The source tests use 0.2C at 0°C to -20°C, then lower rates at colder test points. Program the charger or BMS to reduce current below 0°C and validate the final profile for the selected cell, pack and service-life target.
The source table reports 59.2% capacity retention at -40°C under 0.5C discharge to the stated cutoff. Actual pack-level runtime also depends on enclosure heat transfer, wiring losses, BMS limits and load profile.
+80°C is the upper discharge test and stated operating boundary in the source document, which reports 96.7% capacity retention at 0.5C. Pack safety and thermal behavior still depend on cell lot, enclosure, BMS and application conditions, so the final design should be validated at the intended duty cycle.
Yes. Project options can include JST, Molex or Amphenol connectors, external NTC temperature sensing, custom wire gauges and ruggedized housings. Availability and ratings are confirmed after review of the pack voltage, current, environment and mechanical drawing.
IFR26650-3600-WT Technical Overview
This 3.2V 3600mAh 26650 lithium iron phosphate cell is specified for -40°C to +80°C discharge and -20°C to +50°C charging. The standard cylindrical cell measures 26.2 ± 0.3 mm in diameter and 65.5 ± 0.5 mm in height.
Technical Specifications
| Specification Parameter | Value / Rating | Test Condition / Notes |
|---|---|---|
| Model | IFR26650-3600-WT | Cylindrical LiFePO4 Cell |
| Nominal Voltage | 3.2 V | Operational voltage plateau |
| Nominal Capacity | 3,600 mAh | 0.2C discharge, 2.0V cut-off at 25°C |
| Minimum Capacity | 3,550 mAh | Standard quality screening |
| Standard Charging | 0.2C (720 mA) CC-CV | 3.65V cut-off, 0.02C end current |
| Rapid Charging | 0.5C (1,800 mA) | Supported under monitored BMS conditions |
| Max Continuous Discharge | 2.0C (7.2 A) | Continuous current rating |
| Peak Pulse Discharge | Up to 5.0C (18.0 A) | 10-second burst duration |
| AC Internal Resistance (1 kHz) | Target: ≤25 mΩ (confirm by lot test) | AC measurement at 1 kHz, 25°C, 50% SOC; final value depends on cell lot. |
| Discharge Cut-off Voltage | 2.0 V | Recommended system setting |
| Operating Temp (Charge) | -20°C to +50°C | Controlled charge current at sub-zero |
| Operating Temp (Discharge) | -40°C to +80°C | Factory low/high temp verified |
| Storage Temperature | -20°C to +45°C | 50% State of Charge (SOC) |
| Dimensions | 26.2 ± 0.3 mm (Dia) × 65.5 ± 0.5 mm (H) | Standard 26650 mechanical footprint |
| Cell Weight | Approx. 88.0 ± 2.0 g | Solid cylindrical construction |
Charging Performance by Temperature
The source test table reports charging capacity at rates selected for each temperature. At -20°C and 0.2C, capacity retention is 86.8%. A separate -45°C test at 0.01C reports 62.6%; this test is outside the stated -20°C minimum operating charge temperature and requires engineering validation for any deployment.
| Ambient Temperature | Charging Rate (C-rate) | Average Charging Capacity | Capacity Retention (%) | Design Recommendation |
|---|---|---|---|---|
| 25°C | 0.2C (720 mA) | 3,634 mAh | 100.0% | Standard CC-CV charging |
| 0°C | 0.2C (720 mA) | 3,558 mAh | 97.9% | Full solar charging support |
| -10°C | 0.2C (720 mA) | 3,425 mAh | 94.2% | Direct trickle / solar input |
| -20°C | 0.2C (720 mA) | 3,154 mAh | 86.8% | Controlled sub-zero solar recharge |
| -30°C | 0.1C (360 mA) | 3,171 mAh | 87.2% | Derated charging current via BMS |
| -45°C | 0.01C (36 mA) | 2,277 mAh | 62.6% | Low-power trickle energy harvesting |
Discharge Performance by Temperature
At 0.5C discharge, the source table reports 59.2% retention at -40°C and 96.7% at +80°C. The -50°C data point is a test result outside the specified -40°C minimum discharge operating temperature.
| Operating Temp | Discharge Rate | Delivered Capacity (0.5C) | Capacity Retention Rate | Typical Field Use Case |
|---|---|---|---|---|
| +80°C | 0.5C | ~3,501 mAh | 96.7% | Enclosed metal trackers under direct sunlight |
| +60°C | 0.5C | ~3,527 mAh | 97.4% | Heavy equipment & engine compartment trackers |
| +45°C | 0.5C | ~3,539 mAh | 97.8% | Middle East / Southern US summer deployment |
| +25°C | 0.5C | ~3,620 mAh | 100.0% | Baseline laboratory rating |
| 0°C | 0.5C | ~3,281 mAh | 90.6% | Mild winter outdoor operation |
| -10°C | 0.5C | ~2,965 mAh | 81.9% | Sub-zero cold climate telemetry |
| -20°C | 0.5C | ~2,580 mAh | 71.3% | Winter fleet tracking & cold-chain monitoring |
| -30°C | 0.5C | ~2,600 mAh | 71.8% | High-latitude winter asset deployment |
| -40°C | 0.5C | ~2,143 mAh | 59.2% | Arctic/Nordic remote weather stations & GPS |
| -50°C | 0.5C | ~1,137 mAh | 31.4% | Not specified |
Custom Configurations
Available in 1S2P (3.2V 7.2Ah), 1S3P (3.2V 10.8Ah), 2S1P (6.4V 3.6Ah), 4S1P (12.8V 3.6Ah), and tailor-made pack layouts.

VTCBATT can evaluate the required series-parallel layout, BMS protection, temperature sensing, connector, wiring and enclosure for the final equipment design.