ER34615-1S8P 3.6V 152Ah Li-SOCl2 Battery Pack
Primary lithium battery pack with RHC1550 for OEM equipment integration
| Parameter | Specification |
|---|---|
| Model | ER34615-1S8P |
| Battery chemistry | Primary lithium thionyl chloride (Li-SOCl2); non-rechargeable |
| Configuration | 1S8P: eight ER34615 cells in parallel; RHC1550 shown in the assembly |
| Nominal voltage / capacity | 3.6V / 152Ah |
| Capacity test conditions | 40mA discharge to 2.0V at 23±3°C |
| Nominal energy | 547.2Wh, as marked in the assembly drawing |
| Pack dimensions / weight | 64.5 × 105 × 126.5mm maximum / approximately 820g |
| Maximum continuous / pulse current | 1500mA / 5000mA; pulse duration to be confirmed |
| Ambient operating temperature | -40 to +85°C |
| Storage life / self-discharge | At least 10 years / no more than 2% per year, as specified |
| Connector / leads | JST/XH-3P; UL1007 22AWG; 150±5mm lead length |
| Recommended storage | 10–25°C, never above 30°C; 45–75% RH |
ER34615-1S8P Battery Pack Manufacturer for OEM Projects
VTCBATT supports equipment manufacturers with primary battery pack selection and integration. Review the ER34615-1S8P voltage, discharge requirements, dimensions and harness details against your device specification, then discuss the standard assembly or project-specific requirements with our engineering team.
For an efficient quotation and sample review, provide the load profile, pulse timing, operating environment, battery compartment, mating connector, target service life and expected quantity. The supplied datasheet defines this standard 3.6V 152Ah assembly.
152Ah Rated Capacity on a 3.6V Platform
The eight ER34615 cells are connected in a 1S8P arrangement. Rated capacity is 152Ah at 40mA discharge to 2.0V under 23±3°C conditions, with 547.2Wh nominal energy marked in the assembly drawing. Evaluate available device energy using the actual cut-off voltage, temperature and duty cycle.


-40 to +85°C Ambient Operation
The stated ambient operating range supports evaluation of outdoor and industrial equipment. The specification includes relative-capacity requirements at -40°C, 0°C, 25°C and 45°C under a 40mA discharge. Use those conditions when assessing cold-weather capacity rather than assuming full rated capacity at every temperature.
Specified Continuous and Pulse Current
The datasheet lists a maximum constant discharge current of 1500mA and a maximum pulse current of 5000mA. Pulse duration and repetition conditions are not specified, so confirm the device load profile before selection.


Documented Dimensions, Connector and Leads
The assembly drawing specifies a 64.5 × 105 × 126.5mm maximum envelope, JST/XH-3P connector, UL1007 22AWG leads and 150±5mm wire length. The approximate pack weight is 820g. Match the mechanical mounting, lead routing and red / N/A / black connector pin positions to the device harness.
OEM Pack Engineering Support
Specification and integration support for primary lithium pack projects.

Share average current, pulse amplitude, duration, repetition interval, temperature and device cut-off voltage for an ER34615-1S8P pack review.

Discuss enclosure fit, mounting, JST/XH-3P connector compatibility, UL1007 22AWG leads, pinout and sample evaluation.
Why Choose VTCBATT?
VTCBATT supports customized battery design, standardized manufacturing and responsive engineering service for equipment manufacturers and distributors.
VTCBATT uses controlled manufacturing and test processes to support stable battery supply.
VTCBATT provides custom battery support for long-term equipment projects worldwide.
Applications for Evaluation
Suitability depends on the device load profile, pulse demand, cut-off voltage, operating temperature and available space.

Evaluate for low-standby meter electronics with scheduled readouts. Check radio and valve pulses against the specified current limits.

Consider for remote gas meter readout and telemetry. Confirm actuator demand, pulse duration and device cut-off voltage.

Evaluate for unattended loggers with intermittent sensing and data uploads. Include standby current and transmission duty cycle in sizing.

A candidate for remote sensing nodes that report at intervals. Assess available capacity at the actual operating temperature and load.

Evaluate for low-average-load pressure and condition monitoring nodes. Confirm communication bursts and enclosure conditions.

Consider for temperature logging with periodic wireless reporting. Test capacity at the shipment temperature and expected reporting interval.

Evaluate for distributed soil and weather sensors with intermittent data transmission. Check seasonal temperature and radio pulse demand.

Consider for periodic structural readings and remote telemetry. Validate the sensor, radio and temperature profile as a complete system.
ER34615-1S8P Performance Requirements
Conditions and acceptance requirements listed in the product specification.
- Initial Performance
- Temperature Capacity
Initial Performance Requirements
| Item | Method / conditions | Requirement |
|---|---|---|
| Open-circuit voltage | DC voltmeter measurement | At least 3.60V |
| Minimum rated capacity | 40mA discharge to 2.0V; standard test temperature 23±3°C | At least 152Ah |
Standard tests are specified at 23±3°C and 45–85% relative humidity unless otherwise stated. These are datasheet requirements; measured results for a production lot should be confirmed separately.
Temperature Dependence of Discharge Capacity
| Discharge temperature | Specified relative capacity | Discharge conditions |
|---|---|---|
| -40°C | At least 35% | 40mA to 2.0V |
| 0°C | At least 80% | 40mA to 2.0V |
| 25°C | 100% | 40mA to 2.0V |
| 45°C | At least 95% | 40mA to 2.0V |
The specification requires a three-hour dwell at each test temperature before discharging at 40mA to 2.0V. It describes comparison against capacity at 23°C; its temperature table lists 25°C as the 100% point. The percentages are stated requirements rather than a measured curve for a supplied batch.
No. This is a primary Li-SOCl2 battery pack. The specification explicitly states that the battery must not be recharged. The RHC1550 component shown in the assembly does not make the primary cells rechargeable.
The assembly drawing shows eight ER34615 cells connected in parallel in a single 3.6V voltage group. The pack retains a nominal voltage of 3.6V and provides a rated capacity of 152Ah under the stated discharge conditions.
Rated capacity is specified with a 40mA discharge to a 2.0V cut-off at 23±3°C. Available capacity in a device depends on its temperature, current profile and minimum usable voltage.
Yes. The supplied assembly drawing identifies an RHC1550 component alongside the eight ER34615 cells. Confirm the final assembly revision and the device pulse profile with VTCBATT when ordering.
The datasheet lists a maximum constant discharge current of 1500mA and a maximum pulse current of 5000mA. It does not state a pulse duration or repetition interval, so the complete pulse demand must be reviewed for the intended device.
The maximum pack envelope is 64.5 × 105 × 126.5mm and the approximate weight is 820g. The drawing specifies a JST/XH-3P connector, UL1007 22AWG leads and a 150±5mm lead length. Pin positions are shown as red, N/A and black; confirm the mating connector and polarity before installation.
The datasheet specifies at least 10 years of storage life and annual self-discharge of no more than 2%. Device operating life depends on average load, pulse demand, temperature, cut-off voltage and storage history, and must be evaluated separately.
Provide standby and operating current, pulse amplitude and duration, repetition interval, operating temperature, device cut-off voltage, required service life, enclosure dimensions, mating connector and expected order quantity. Refer to the downloadable datasheet and assembly drawing for the standard pack.
Integrating a 3.6V 152Ah Primary Battery Pack
The ER34615-1S8P combines eight ER34615 cells in parallel with the RHC1550 component identified in the assembly drawing. It is a single-voltage-group primary pack for equipment designed around a 3.6V supply. The blue sleeve, wired connector and rectangular envelope shown in the product photographs should be matched to the device enclosure and installation arrangement.
Review the complete load profile
Start with standby current, average operating current and each startup or communication pulse. Check the 1500mA maximum constant current and 5000mA maximum pulse figure together with the device cut-off voltage. A pulse-current figure without duration and repetition information is insufficient for confirming a device match. Submit the complete waveform or duty-cycle description for engineering review.
Potential application projects
Candidate projects include remote data loggers, environmental telemetry, industrial monitoring electronics and utility metering equipment where a 3.6V primary pack and the stated size are appropriate. Selection should follow an assessment of the enclosure, temperature range and full current profile. The product page does not guarantee suitability for every device in these categories.
Mechanical and electrical integration
Reserve space for the 64.5 × 105 × 126.5mm maximum pack envelope, the lead exit and connector access. The specified JST/XH-3P connector has red and black power leads with the middle position marked N/A in the drawing. The standard leads are UL1007 22AWG with a length of 150±5mm. Confirm mounting support for the approximately 820g assembly and verify the final pinout against the device harness.
Temperature and storage planning
The ambient operating range is -40 to +85°C. The datasheet separately lists temperature-dependent capacity requirements measured with a 40mA discharge to 2.0V. Storage recommendations are 10–25°C, never above 30°C, at 45–75% relative humidity in a cool, dry, ventilated environment. Keep the primary pack in its original packaging until installation and follow the handling guidance in the specification.
Documentation for your project
Download the ER34615-1S8P 3.6V 152Ah specification and assembly drawing. The performance tables reproduced on this page are specification requirements; acceptance and measured qualification evidence for a particular order should be confirmed during the project review.