x
Send Your Inquiry Today

eCall Battery Solutions

Wide-temperature Li-ion and LiFePO4 backup battery solutions for eCall and NG-eCall emergency communication systems. 

  • −40°C Low-Temperature Options
  • Up to +85°C Application Designs
  • High-Pulse Backup Power

eCall Battery Solutions for Automotive Emergency Systems

An eCall battery is a backup battery that keeps the vehicle emergency-call system operating if the main vehicle power is disconnected or damaged during a crash. See our automotive electronics battery solutions for other vehicle systems.

It may remain on standby for years but must deliver sufficient energy and peak current immediately when an emergency call is triggered. Low temperature, battery aging, modem current pulses and system cutoff voltage can all reduce the usable backup energy.

 

VTCBATT develops custom Li-ion and LiFePO4 battery packs for eCall and NG-eCall systems. Packs can be designed with wide-temperature cells, NTC sensing, PCM/BMS protection, custom wires and connectors.

Each eCall battery pack is designed around the actual load profile, peak current, minimum system voltage, temperature range and required service life.

Read More

eCall Battery Models

Explore typical eCall battery models for eCall and NG-eCall systems. Custom battery packs are available based on voltage, peak current, temperature requirements, backup time and installation space.

ModelChemistryVoltageCapacityApplication TemperatureTypical Application
VTC14500RLi-ion3.6V750 mAh−40~+85°CCompact eCall / TCU
VTC18650VLi-ion3.6V2900mAh−40~+85°CLong Standby eCall
VTC21700P50BLi-ion3.6V5000mAh−40~+85°CHigh Capacity eCall backup design
VTC18650HLiFePO43.2V1600mAh−40~+85°CLong-life Backup
VTC26650FLiFePO43.2V3600mAh −40~+85°C NG-eCall,emergency backup system

*Application temperature refers to the target vehicle or system environment and does not mean that every cell supports continuous charging or discharging across the full stated range. Available charging, discharging, storage and survival temperature limits depend on the selected cell, current profile and project requirements. Final specifications should be confirmed during engineering review.

eCall Battery Chemistry Comparison

Li-ion, LiFePO4 and NiMH can all be used in eCall backup batteries. Each chemistry has different trade-offs in size, safety, temperature performance and aging. 

ChemistryStrengthsLimitationsTypical Selection Reason
Li-ionHigh energy density, compact sizeNeeds strict protection and aging validationSpace-limited TCU, and eCall modules
LiFePO4Good safety, thermal stability, long lifeLower energy density and nominal voltageRobust packs focused on safety and lifetime
NiMHAutomotive history, simple pack designHigher self-discharge, lower energy densityEstablished automotive platforms and OEM qualification history 

Engineering Risks in eCall Battery Design

Voltage Sag & Peak Current

Cold pulse voltage can decide pass or fail.

Risk: High-current modem pulses can cause voltage sag, especially during network attach, data transmission or retries. At low temperature, internal resistance increases, and the system may reset even if the battery still has remaining capacity.

Check: Test pulse-load voltage at room temperature, low temperature, beginning of life and end of life.

Wide-Temperature Design

Temperature range affects power, aging and charging limits.

Risk: An eCall battery must work across the vehicle’s thermal environment. Low temperature reduces power and increases voltage sag. High temperature accelerates aging and may restrict safe charging.

Check: Define discharge, charge, storage and survival temperature separately.

Long-Term Standby & Aging

The battery must still work after years of standby.

Risk: Capacity can fade and internal resistance can increase during long standby life. Self-discharge and battery-management quiescent current can also reduce available energy during vehicle storage.

Check: Validate the emergency load profile at end of life, not only with a fresh battery.

How to Calculate eCall Battery Capacity

eCall battery capacity should be calculated from the real emergency load profile. Add the energy required for standby, GNSS, network attach, MSD transmission, voice call and callback standby. Then apply derating for efficiency, temperature, aging and design margin.

 

Required capacity = load energy ÷ efficiency ÷ cold derating ÷ end-of-life retention × (1 + design margin)

V

V

%

%

%

%
Load Energy0.174 Wh
Required Battery Energy0.415 Wh
Cell-Level Capacity112 mAh
Peak Current Check1,500 mA

ModeAverage Current (mA)Peak Current (mA)Duration (s)Energy (Wh)Equivalent (mAh)
Sleep / standby0.0041.03
Wake-up0.0010.17
GNSS positioning0.0051.37
Network attach0.0082.14
MSD transmission0.0051.28
Voice call0.11430.81
Callback standby0.03810.27

Engineering Note: This calculator estimates one defined eCall load sequence. Final battery selection must also verify pulse voltage drop, internal resistance, cold-crank temperature, cell aging, storage life, recharge strategy and the required automotive qualification level.

What Is an eCall Battery?

An eCall battery is a dedicated backup battery for a vehicle’s emergency-call system. It provides power when the main vehicle electrical supply is lost, disconnected or damaged during an accident.

Unlike the main car battery, an eCall backup battery is designed specifically for emergency communication. It may remain in standby for years but must still deliver reliable power when an emergency call is triggered.

For this reason, eCall battery selection must consider not only capacity, but also peak current, low-temperature performance, voltage limits, aging and required backup time.

How Does an eCall Battery Work?

During normal driving, the vehicle electrical system powers the eCall module and maintains the backup battery. If main power is lost, the system switches to the eCall battery to complete the emergency communication sequence.

Typical eCall Backup Power Sequence

  1. Main Vehicle Power – Powers the eCall module and maintains the backup battery.
  2. Power Loss & Switchover – The system switches to backup battery power.
  3. GNSS Positioning – The vehicle location is determined.
  4. Network & MSD Transmission – The modem connects and sends the Minimum Set of Data.
  5. Voice Communication – Backup power supports the emergency call.
  6. Callback Availability – Remaining energy supports standby and callback functions.

Typical eCall Battery Load Profile

An eCall battery sees very different loads during standby, crash detection, GNSS positioning, network connection, MSD transmission and voice communication. Battery sizing should therefore consider both total energy and peak current capability.

At low temperature, peak-current performance can be more critical than nominal capacity alone.

Operating PhaseLoad BehaviorDesign Impact
Standby / MonitoringVery low current for long periodsSelf-discharge, quiescent current and aging matter.
Crash / Wake-UpFast change to active modeBattery must deliver current immediately, even when cold.
GNSS PositioningModerate active loadLonger acquisition time increases energy use.
Network AttachShort high-current burstsCheck internal resistance and voltage sag.
MSD TransmissionShort data transferVoltage must stay above modem limits.
Voice CommunicationSustained active loadAllow margin for call duration, aging and temperature.
Callback WindowIntermittent standby and reactivationSystem standby current can consume significant energy.

Custom eCall Battery Development Process

A custom eCall battery project moves from requirement review to cell selection, pack design, prototype testing and system validation. 

 

Start Your eCall Battery Design

Send us your voltage range, load profile, peak current, temperature range, backup-time requirement and available battery space. Our engineering team can review the requirements and recommend a suitable eCall battery configuration.

Request an eCall Battery Design Review

    What is an eCall battery?

    An eCall battery is a dedicated backup battery for the vehicle emergency-call system. It keeps the eCall unit powered if the main vehicle power is lost or damaged during an accident. The battery supports key emergency functions such as GNSS positioning, MSD data transmission and voice communication.

    Is an eCall battery the same as a car battery?

    No. The car battery powers the vehicle electrical system. The eCall battery is a dedicated backup battery for emergency communication electronics. It is usually smaller, but it must support standby life, modem pulse current, temperature requirements and reliable emergency operation if main power is lost.

    What battery chemistries are used for eCall systems?

    Common eCall battery chemistries include Li-ion, LiFePO4 and NiMH. Li-ion favors compact size and energy density, LiFePO4 favors thermal stability and long life, while NiMH remains common in some established automotive platforms. The final choice depends on voltage, temperature, lifetime and system requirements.

    Can VTCBATT make custom eCall battery packs?

    Yes. VTCBATT can develop custom battery packs for eCall, NG-eCall, TCU and T-Box applications. Customization can include cell type, wire harness, connector, NTC, PCM or BMS, insulation, label and pack dimensions.

    What information is needed for an eCall battery design?

    The key inputs are voltage range, load profile, peak current, backup time, operating temperature, charging method, available space, connector type and target service life. Connector type, wire length, NTC requirement, pack size and mounting method are also important for a custom pack.

    Why is peak current important for eCall batteries?

    Cellular modems can draw short high-current pulses during network connection, data transmission and retries. The battery must keep the system voltage above the required limit during these pulses, especially at low temperature and end of life.

    Does NG-eCall need a different battery?

    Not always. NG-eCall uses packet-switched 4G or 5G network architecture, so modem behavior may differ from legacy 2G/3G systems. The battery should be checked with the actual NG-eCall module, firmware and network conditions before final selection.

    What temperature range is required for eCall battery packs?

    eCall battery projects may need to withstand automotive environments extending from around -40°C to +85°C, depending on installation location and OEM requirements. Allowable charging, discharging, storage and survival temperatures depend on the selected cell and pack design.

    How long should an eCall battery last?

    The service life depends on the OEM or Tier 1 requirement. Many eCall backup batteries are designed for several years of standby operation, and some projects may require 3 years, 5 years, 10 years or a vehicle-life target. End-of-life performance should be confirmed by aging and system-level backup tests.

    Can one eCall battery model fit all vehicles?

    Usually no. Different vehicles and eCall modules can have different voltage limits, current profiles, backup-time requirements, connectors, temperature classes and installation spaces. A standard model can help narrow the choice, but the final battery still needs to match the project requirements.

    What Is NG-eCall and How Does It Affect Battery Design?

    NG-eCall means next-generation eCall. It moves emergency communication from legacy 2G/3G circuit-switched networks to packet-switched 4G and 5G networks using IMS.

    This changes how the modem registers, transmits data, handles retries and supports voice communication. NG-eCall does not automatically require a larger backup battery, but its real power profile should be validated using the target modem, firmware and network conditions.

    NG-eCall Standards

    Updated EU eCall requirements also introduce test procedures for backup and secondary power supplies to verify that the eCall system remains operational when the vehicle’s main power supply is disconnected. 

    ReferenceRelevanceMandatory Date / StatusKey Description
    EN 17184:2024NG-eCall high-level application protocols1 January 2027High-level application protocols (HLAP) for Next Generation eCall over IMS/packet networks.
    EN 17240:2024NG-eCall end-to-end conformance testing1 January 2027End-to-end conformance test specifications and test suites for NG-eCall IVS and PSAP.
    Regulation (EU) 2025/1871Updates eCall technical and backup-power test requirementsApplicable / EnactedEuropean Commission delegated regulation updating technical requirements, testing procedures, and backup power supply verification.

     

    Custom Battery Pack Integration

    A custom eCall battery pack is more than a group of cells. It combines the selected cell with protection circuits, wiring, connectors, NTC temperature sensing, insulation, mechanical fixation, labels and validation documents. These details must match the customer’s vehicle platform.

    Common customization points include cell configuration, cell format, wire harness length, connector type, NTC value, PCM or BMS design, flame-retardant materials, mounting method, pack size and traceability label.

    Typical cell formats include 14500, 18650, pouch and prismatic cells. The pack may use a 1S design or a multi-cell configuration, depending on system voltage and backup power requirements.

    The backup battery for eCall should be designed as part of the vehicle electronics architecture.

    Before recommending a final pack design, the supplier should confirm the load profile, operating temperature range, target lifetime, charging method, available space, connector requirement and validation plan.

     

    Ecall Battery Testing and Validation

    eCall battery validation should confirm that the pack can still support the emergency communication function after temperature exposure, aging and electrical stress. VTCBATT verifies both battery-level performance and system-level backup operation. 

     

    eCall Battery Discharge Curve from −40°C to +85°C

     

    A wide-temperature battery sample was tested under low- and high-temperature conditions to evaluate discharge performance, voltage stability and physical condition across the target automotive temperature range.

    At −40°C, the key checks are usable capacity, voltage sag and pulse-current capability. At +85°C, the test focuses on voltage stability, swelling, leakage and other signs of thermal stress. 

    Test ParameterCondition
    Battery ModelVTC18650C
    ChemistryLi-ion
    Nominal Capacity2500 mAh
    Test Temperatures−40°C / −20°C / 25°C / 60°C / +85°C
    Discharge Current1250 mA
    Cut-off Voltage2.75 V

    In addition to temperature testing, a complete eCall battery validation program may include the following tests:

     

    Validation TestWhat It Verifies
    Capacity testAvailable energy at defined current, temperature and cutoff voltage.
    Pulse-load testMinimum voltage during modem transmit bursts and network attach.
    Cold-soak dischargeEmergency function after low-temperature exposure.
    High-temperature storageCalendar aging, swelling, leakage, impedance growth and retention risk.
    Thermal cyclingPack construction, welds, harnesses, connectors and insulation stability.
    Vibration and shockMechanical integrity under vehicle conditions.
    Charge strategy validationSafe recharge, float behavior, diagnostics and recovery after deep discharge.
    System-level call testActual eCall completion using the target module, antenna, firmware and network profile.

    Technical References

    • Commission Delegated Regulation (EU) 2025/1871 — Updates EU eCall standards, technical requirements and backup-power test procedures. citeturn841707search1
    • EN 17184:2024 — Defines high-level application protocols for NG-eCall over IMS packet-switched networks.
    • EN 17240:2024 — Defines end-to-end conformance testing for NG-eCall IVS and PSAP communication.
    • Texas Instruments TIDA-050031 — Automotive eCall backup-power reference design covering LiFePO4 backup power, charging and boost conversion. citeturn841707search0

    Standards and regulations should be verified against the latest official revision and project-specific type-approval requirements.

    Get an Instant Quote
           
    contact

    Send Your Inquiry Now

    Looking for the perfect battery solution? Our expert engineering team is ready to support you from idea to delivery. Whether you need custom voltage, size, or application-specific design, we’re here to make it happen. Get in touch today and let us power your success—one battery at a time!
    Get an Instant Quote

    MEET VTCBATT

    Meet VTCBATT at electronica 2026.

    Bring your battery project to Munich. Meet our team to explore custom lithium and wide temperature battery solutions for your next device.

    WHEN
    November 10–13, 2026
    WHERE
    Messe München · Munich, Germany
    BOOTH
    Hall A5 · 171/2
    Plan your visit

    Let’s talk batteries. Let’s build what’s next.

    Scroll to Top