ER34615M 3.6V 14500mAh Li-SOCl2 High-Rate Primary Lithium Battery
4A pulse rating for defined intermittent peak loads
| Parameter | Specification |
|---|---|
| Model | ER34615M |
| Battery Type | Li-SOCl2 primary lithium thionyl chloride cell |
| Nominal Voltage | 3.6V |
| Nominal Capacity | 14.5Ah |
| Capacity Test Condition | 15mA discharge at +25°C to 2.0V |
| Maximum Recommended Continuous Discharge | 1800mA |
| Maximum Pulse Current | 4000mA |
| Operating Temperature | -60 to +85°C |
| Cell Dimensions / Reference Size | Ø34 × 61.5mm max / D size |
| Approximate Weight / Rechargeability | Approx. 110g / Primary, non-rechargeable |
3.6V Primary Lithium Power with Defined Pulse Output
ER34615M is a 3.6V 14.5Ah Li-SOCl2 primary cell in a D size cylindrical format. Its listed continuous and pulse output supports devices with a defined intermittent load profile. Compare the exact current waveform, temperature and end voltage with the limits in this specification. The Li-SOCl2 battery category includes primary cells for metering, backup and remote monitoring equipment.
Non-rechargeable cell. Confirm continuous current, pulse profile, temperature, storage and voltage cut-off for the target device.
High-Rate Li-SOCl2 Output for Intermittent Loads
Use current and pulse limits as design inputs; confirm the complete duty cycle with VTCBATT.
Maximum pulse current: 4000mA
Recommended maximum: 1800mA
-60 to +85°C
Annual self-discharge below 1% at +25°C, as listed
4000mA Maximum Pulse Current
The ER34615M datasheet lists a maximum pulse current of 4000mA. Validate pulse duration, spacing, baseline current, temperature and end voltage in the target device before design release.


1800mA Recommended Continuous Current
A maximum recommended continuous discharge current of 1800mA is listed for the cell. This defined output supports engineering selection for low-power equipment with brief higher-current events, subject to the complete duty cycle.
Wide Operating Temperature
The documented operating range is -60 to +85°C. Capacity and pulse voltage change with temperature, so system design should include the expected environment and cut-off threshold.


Low Self-Discharge for Standby
The product sheet lists annual self-discharge below 1% after one year at +25°C. This supports standby-oriented metering, backup and remote sensing designs when stored and operated within the specified conditions.
OEM Battery Engineering Support
Specification and integration assistance for primary lithium equipment projects.

Share continuous current, pulse amplitude, duration, spacing, temperature and cut-off voltage for a cell-fit review.

Discuss cell-holder dimensions, welded terminals, lead and connector options, labeling and sample evaluation.
Why Choose VTCBATT?
VTCBATT supports customized battery design, standardized manufacturing and responsive engineering service for equipment manufacturers and distributors.
VTCBATT uses controlled manufacturing and test processes to support stable battery supply.
VTCBATT provides custom battery support for long-term equipment projects worldwide.
ER34615M Applications
Eight source-aligned use cases for primary cells with intermittent current demand.

Long-standby utility meter electronics with short scheduled readout pulses.

Alarm and security nodes that draw a low standby current and brief event-driven pulses.

Compact roadside sensing and control units; not the gate motor or barrier drive.

Industrial controller memory and real-time-clock backup circuits.
Periodic location reporting and standby in logistics and equipment trackers.

Low-power vehicle sensing and telemetry modules, not engine-starting loads.

Compact instruments with documented current profiles and suitable cell holders.

Environmental and utility data loggers that transmit intermittently.
No. This is a Li-SOCl2 primary lithium cell and must not be recharged.
The nominal voltage is 3.6V and the datasheet nominal capacity is 14.5Ah under this condition: 15mA discharge at +25°C to 2.0V .
The listed maximum recommended continuous current is 1800mA; maximum pulse current is 4000mA. Validate pulse duration and recovery intervals for your exact device.
It is intended for primary-cell applications within its specified continuous and pulse limits, not as a general motor or rechargeable power source.
The stated range is -60 to +85°C. Available capacity and pulse voltage vary with temperature and load.
VTCBATT can review cell termination, connection, labeling, sampling and factory-direct wholesale requirements for OEM/ODM projects.
Related Li-SOCl2 Primary Lithium Cells
ER34615M 3.6V 14500mAh Li-SOCl2 High-Rate Primary Battery
The ER34615M is a 3.6V lithium thionyl chloride primary cell for equipment that needs long standby capability together with defined continuous and intermittent pulse-current support. Its D size cylindrical format is suited to systems whose load profile can be engineered within the cell’s documented current, temperature and cut-off limits. This battery is non-rechargeable.
Key Electrical Specifications
| Parameter | Specification |
|---|---|
| Model | ER34615M |
| Battery Type | Li-SOCl2 primary lithium thionyl chloride cell |
| Nominal Voltage | 3.6V |
| Nominal Capacity | 14.5Ah |
| Capacity Test Condition | 15mA discharge at +25°C to 2.0V |
| Maximum Recommended Continuous Discharge | 1800mA |
| Maximum Pulse Current | 4000mA |
| Operating Temperature | -60 to +85°C |
| Cell Dimensions / Reference Size | Ø34 × 61.5mm max / D size |
| Approximate Weight / Rechargeability | Approx. 110g / Primary, non-rechargeable |
Continuous and Pulse Discharge Design
A separate ER34615M technical sheet specifies 4000mA pulses for 0.1 second every 2 minutes under its stated test setup, plus a maximum recommended current of 1800mA. The newer specification sheet contains a current-unit typo (“2000mAh”); engineering review should confirm the applicable continuous-current limit for the ordered cell.
Maximum ratings are not a substitute for application validation. Review pulse amplitude, duration, repetition interval, base current, operating temperature, cell history and equipment cut-off voltage together. Do not charge the cell or connect it to a charging circuit.
Cell Dimensions and Construction
The ER34615M follows the D size reference envelope at Ø34 × 61.5mm max, with an approximate cell weight of 110g. The cylindrical stainless-steel case, hermetic glass-to-metal seal and non-flammable electrolyte are listed among the product features. Avoid direct soldering to the cell; select a version with pre-welded leads or tabs when required.
Operating Temperature and Storage
The specified operating range is -60 to +85°C. The recommended storage condition is up to 30°C. Available capacity and the voltage response at the start of a pulse vary with current, temperature, cut-off voltage and storage history. The product sheet lists annual self-discharge below 1% after one year at +25°C.
Typical Applications
Potential application fit depends on the equipment’s verified load profile. Common application categories include:
- Smart meters and instruments
- Memory and backup power
- Wireless alarms and tracking
- Automated electronics
- Electronic toll collection
- Military equipment
- GPS tracking
- Real-time clocks

Smart Water Meter Modules
Long-standby utility meter electronics with short scheduled readout pulses.

Wireless Alarm Sensors
Alarm and security nodes that draw a low standby current and brief event-driven pulses.

Electronic Toll Collection
Compact roadside sensing and control units; not the gate motor or barrier drive.

PLC Memory Backup
Industrial controller memory and real-time-clock backup circuits.
![]()
GPS Asset Tracking
Periodic location reporting and standby in logistics and equipment trackers.

Automotive Sensor Electronics
Low-power vehicle sensing and telemetry modules, not engine-starting loads.

Professional Instruments
Compact instruments with documented current profiles and suitable cell holders.

Remote Data Loggers
Environmental and utility data loggers that transmit intermittently.
Handling and Safety Considerations
This is a primary cell: do not charge, short-circuit, overheat, dismantle or crush it. Do not solder directly to the cell surface; use a pre-tabbed or pre-wired configuration where needed. Do not mix used and new cells, different cell types or products from different manufacturers in one equipment assembly. Follow applicable local collection and disposal requirements.
OEM and Wholesale Supply
VTCBATT supports factory-direct supply, sample evaluation and OEM/ODM customization for equipment makers, distributors and battery integrators. Share the maximum continuous current, pulse waveform, repetition interval, ambient-temperature profile, end-of-life voltage, cell-holder dimensions and desired terminal configuration for an engineering fit review.