x
Send Your Inquiry Today
  • VTCBATT IFR32140-8S6P LiFePO4 battery pack labeled 25.6V 90Ah and 2304Wh beside a test analyzer
  • Labeled VTCBATT IFR32140-8S6P 25.6V 90Ah LiFePO4 battery pack connected to an illustrative bench power supply
  • Labeled VTCBATT IFR32140-8S6P 25.6V 90Ah LiFePO4 battery pack being checked with a caliper
  • VTCBATT IFR32140-8S6P LiFePO4 battery pack labeled 25.6V 90Ah and 2304Wh beside a test analyzer
  • Labeled VTCBATT IFR32140-8S6P 25.6V 90Ah LiFePO4 battery pack connected to an illustrative bench power supply
  • Labeled VTCBATT IFR32140-8S6P 25.6V 90Ah LiFePO4 battery pack being checked with a caliper

IFR32140-8S6P 25.6V 90Ah LiFePO4 Battery Pack

25.6V 90Ah LiFePO4 Battery

The IFR32140-8S6P is a 25.6V, 90Ah LiFePO4 battery pack with 2304Wh nominal energy. Review the specification values and operating limits below before system selection.

ModelIFR32140-8S6P (specification cover)
Nominal voltage25.6V
Rated capacity / energy90Ah / 2304Wh
Minimum capacity87Ah at 18A discharge to 20V cutoff
Maximum charge voltage29.2V
Maximum discharge current20A, subject to temperature limits
Maximum dimensions / weight165 × 270 × 365mm / 14kg

Configuration note: the cover says 8S6P; the outline drawing says 8S5P. Confirm production configuration with VTCBATT.

IFR32140-8S6P LiFePO4 Battery Manufacturer in China

The product specification identifies VTC Power Co., Ltd. as the manufacturer and supplier of this cylindrical LiFePO4 battery pack. Key ratings are 25.6V nominal voltage, 90Ah rated capacity, 2304Wh nominal energy, 29.2V maximum charge voltage, and 20A maximum discharge current.

VTCBATT provides custom lithium battery engineering and OEM/ODM support. Share the available enclosure space, load profile, charger, operating temperature and target capacity so the engineering team can review fit for your equipment.

For other 24V-class LiFePO4 options, see the 24V LiFePO4 battery range. Compare each model’s chemistry, current limits, dimensions and operating conditions before selection.

Read More
Electrical Specifications

Key Battery Ratings

Core values taken from the supplied specification.

Nominal Voltage

Rated 25.6V for compatible LiFePO4 system design.

Rated Capacity

90Ah rated capacity; verify load and runtime needs.

Nominal Energy

2304Wh nominal energy; calculate usable runtime separately.

Maximum Charge Voltage

29.2V maximum; follow the specified charging profile.

Capacity and Energy Ratings

The rated capacity is 90Ah and nominal energy is 2304Wh. The specification sets minimum capacity at 87Ah when the pack is discharged at 18A to a 20V cutoff. This figure applies to the stated test condition.

Illustrative test setup only; the image does not show a measured result.

VTCBATT IFR32140-8S6P LiFePO4 battery pack labeled 25.6V 90Ah and 2304Wh beside a test analyzer
Labeled VTCBATT IFR32140-8S6P 25.6V 90Ah LiFePO4 battery pack connected to an illustrative bench power supply

Standard and Rapid Charging

Standard charging is 9A constant current followed by constant voltage at 29.2V, with a 0.9A cutoff. The specification lists 18A as the rapid charge current. Its temperature table limits charging current to 4.5A from 0 to 10C, 9A above 10 to 20C, and 18A above 20 to 45C.

Use a charger configured for this LiFePO4 profile and observe the temperature-based current limits.

Temperature-Based Discharge Limits

The listed discharge range is -20 to 50C, with current limits that vary by temperature: 4.5A from -20 to 0C; 9A above 0 to 10C; 20A above 10 to 45C; and 18A above 45 to 50C. These limits are from the product specification.

The environmental-chamber visual is illustrative and does not represent a measured result.

Labeled VTCBATT IFR32140-8S6P 25.6V 90Ah LiFePO4 battery pack inside an illustrative environmental chamber
Labeled VTCBATT IFR32140-8S6P 25.6V 90Ah LiFePO4 battery pack being checked with a caliper

Dimensions and Installation Fit

The specification lists maximum dimensions of 165 x 270 x 365 mm and weight of 14 kg. Confirm orientation, mounting points, cable exit, clearances and tolerances from the controlled mechanical drawing before installation.

The caliper visual is illustrative; it is not a dimensional drawing.

Technical Documentation

Download the IFR32140-8S6P Specification

25.6V 90Ah LiFePO4 Battery Specification

See the electrical characteristics, operating limits, dimensions and cycle-life test procedures.

LiFePO4 Battery Features

Features of the IFR32140 Battery Pack

Review the model-specific storage, temperature and configuration details.

VTCBATT IFR32140-8S6P LiFePO4 battery pack labeled 25.6V 90Ah and 2304Wh beside a test analyzer
Storage and Self-Discharge

The supplied specification lists storage limits of −20 to 50°C for up to one month, −20 to 45°C for up to six months and −20 to 25°C for up to one year. It does not state a self-discharge percentage for this pack; request pack-specific storage and state-of-charge guidance for long-term projects.

Labeled VTCBATT IFR32140-8S6P 25.6V 90Ah LiFePO4 battery pack inside an illustrative environmental chamber
Temperature and Overheat Control

Charging is specified from 0 to 45°C and discharging from −20 to 50°C, with current limits changing by temperature. The specification also says discharge must stop if cell surface temperature exceeds 70°C. Apply the full limits when integrating the pack.

Labeled VTCBATT IFR32140-8S6P 25.6V 90Ah LiFePO4 battery pack being checked with a caliper
Cylindrical Cell Configuration

The specification cover identifies cylindrical IFR32140 cells in an 8S6P model, while the outline drawing is marked 8S5P. Confirm the final production configuration with VTCBATT before ordering or system integration.

Get an Instant Quote
VTCBATT Manufacturer

Why Choose VTCBATT?

Customized design, manufacturing support and service for battery projects.

Modern Manufacturing

VTCBATT describes an automated and monitored manufacturing process from material preparation through cell testing. Contact the team to discuss the quality controls and records applicable to this battery project.

VTCBATT’s company story describes more than 20 years of customer partnerships across over 50 countries, including long-term cooperation and tailored battery support.

Potential Applications

Eight Possible 25.6V System Applications

Illustrative examples only. Verify system voltage, current, runtime, charger, temperature and physical fit before selection.

VTCBATT backup power application scene; illustrative potential application with a small VTCBATT selling-point label
Backup Power for Control Cabinets

Potential fit for low-power monitoring and control backup in a system designed for a 25.6V LiFePO4 source. Confirm continuous and peak current, runtime, charger and enclosure requirements.

VTCBATT solar storage application scene; illustrative potential application with a small VTCBATT selling-point label
Off-Grid Solar Monitoring

May be considered for low-load solar monitoring equipment when the controller matches the specified 29.2V charge limit and temperature-based current limits. Verify daily energy use and installation conditions.

VTCBATT network continuity application scene; illustrative potential application with a small VTCBATT selling-point label
Telecom and Network Continuity

Could support selected network access equipment designed for a 25.6V battery source. Check actual load and startup current against the 20A maximum discharge limit, plus runtime and charging needs.

VTCBATT security system application scene; illustrative potential application with a small VTCBATT selling-point label
Security System Backup

Potential use for compatible CCTV or perimeter-security control electronics with modest current demand. Verify system voltage, peak load, charger profile, runtime and operating temperature.

VTCBATT remote monitoring application scene; illustrative potential application with a small VTCBATT selling-point label
Remote Monitoring Stations

Could be evaluated for remote sensors and monitoring equipment where the load profile fits the pack limits. Confirm cold-temperature current derating, runtime and service access.

VTCBATT portable field power application scene; illustrative potential application with a small VTCBATT selling-point label
Portable Field Service Equipment

May suit selected portable diagnostic equipment designed for 25.6V LiFePO4 power. Check the 14kg pack weight, dimensions, cable connections, peak current and required operating time.

VTCBATT emergency lighting application scene; illustrative potential application with a small VTCBATT selling-point label
Emergency Lighting Controls

Potential fit for low-power lighting control or monitoring equipment when system voltage and discharge current are compatible. Confirm required backup duration and temperature conditions.

VTCBATT marine auxiliary power application scene; illustrative potential application with a small VTCBATT selling-point label
Marine Auxiliary Electronics

Could be reviewed for compatible auxiliary instruments on systems designed around 25.6V LiFePO4. Confirm charging equipment, current demand, enclosure protection and marine installation requirements.

What are the rated voltage, capacity and energy?

The specification lists 25.6V nominal voltage, 90Ah rated capacity and 2304Wh nominal energy.

What minimum capacity is specified?

At least 87Ah when discharged at 18A to a 20V cutoff, as stated in the specification.

What charging profile does the specification give?

Standard charge is 9A constant current followed by 29.2V constant voltage, ending at 0.9A. The listed rapid charge current is 18A, subject to the temperature-based charging current limits.

What are the discharge current and temperature limits?

Maximum discharge current is listed as 20A. The temperature table specifies 4.5A from -20 to 0C, 9A above 0 to 10C, 20A above 10 to 45C, and 18A above 45 to 50C.

What are the pack dimensions and weight?

The specification lists maximum dimensions of 165 x 270 x 365 mm and a weight of 14 kg. Verify clearances and mounting from the controlled drawing.

What does the specification state about cycle life?

The specification reports at least 4,000 cycles to 70% under a 0.2C test and at least 3,000 cycles to 80% under a 0.5C test at 25 +/- 2C. For a 90Ah pack, 0.5C equals 45A, above the same document’s listed maximum charge and discharge currents. Treat that figure as a reported test condition, not a use recommendation or service-life guarantee, and confirm the test configuration with VTCBATT.

Which cell layout should I confirm before ordering?

The specification cover identifies the model as IFR32140-8S6P, while its outline drawing is marked 8S5P. Confirm the production configuration with VTCBATT before ordering or integrating the pack.

Related 24V LiFePO4 Products

Compare Capacity and Pack Construction

IFR32140-8S6P 25.6V 90Ah LiFePO4 battery overview

This rechargeable lithium iron phosphate battery pack is rated at 25.6V and 90Ah, giving 2304Wh nominal energy. The product specification identifies VTC Power Co., Ltd. as its manufacturer and supplier. Use the electrical limits and test conditions below when checking whether the pack suits a particular system.

Key specifications

Model on specification coverIFR32140-8S6P
ChemistryLiFePO4 (lithium iron phosphate)
Nominal voltage25.6V
Rated capacity90Ah
Minimum capacity87Ah at 18A discharge to 20V cutoff
Nominal energy2304Wh
Internal impedance50mOhm maximum
Maximum charge voltage29.2V
Standard charge9A CC/CV; 29.2V constant voltage; 0.9A cutoff
Rapid charge current18A, subject to temperature limits
Standard discharge7.5A; 20V cutoff
Maximum discharge current20A, subject to temperature limits
Maximum dimensions165 x 270 x 365 mm
Weight14kg

Charging profile and current limits

Standard charging uses 9A constant current, then constant voltage at 29.2V until current falls to 0.9A. The specification separately lists an 18A rapid charge current. Its temperature table sets maximum charge current at 4.5A from 0C to 10C, 9A above 10C to 20C, and 18A above 20C to 45C. Apply the relevant limit for the actual battery temperature and use a charger designed for LiFePO4 chemistry.

Charging modeCurrent and profileNotes
Standard9A CC/CV; 29.2V CV; 0.9A cutoffStandard profile listed in the specification
Rapid18A listedTemperature table permits up to 18A only above 20C to 45C; confirm rapid-charge termination settings

Apply the relevant current limit for the actual battery temperature.

Standard discharge is 7.5A to a 20V cutoff. The listed maximum discharge current is 20A, with temperature-dependent limits: 4.5A from -20C to 0C; 9A above 0C to 10C; 20A above 10C to 45C; and 18A above 45C to 50C.

Operating and storage temperature

The specification lists charging operation from 0C to 45C and discharge operation from -20C to 50C, subject to the current limits above. For storage, it lists -20C to 50C for up to one month, -20C to 45C for up to six months, and -20C to 25C for up to one year. Follow the product-specific handling instructions and confirm conditions before installation.

Cycle-life test conditions

The specification lists at least 4,000 cycles to 70% capacity using a 0.2C charge/discharge procedure at 25 +/- 2C: charge by CC/CV to 29.2V with a 750mA cutoff, rest 10 minutes, discharge at 0.2C to 20V, and rest 20 minutes. It lists at least 3,000 cycles to 80% capacity under a 0.5C procedure: charge by CC/CV to 29.2V with a 750mA cutoff, rest 10 minutes, discharge at 0.5C to 20V, and rest 30 minutes. For this 90Ah pack, 0.5C equals 45A, above the same document’s listed maximum charge current of 18A and maximum discharge current of 20A. Treat this as a recorded test condition, not a normal operating recommendation or guaranteed service life; ask VTCBATT to confirm the test configuration before relying on the figure.

Applications and system fit

Evaluate this pack for equipment designed for a 25.6V LiFePO4 source. Check continuous and peak load current, inrush, required runtime, charger profile, temperature, mounting and cable connections. Potential use in 24V-class backup or off-grid equipment should be confirmed against these requirements; no specific customer deployment is implied. See the 24V LiFePO4 battery range for other models.

Configuration confirmation

The specification cover identifies model IFR32140-8S6P, but the outline drawing in the same document is marked 8S5P. Confirm the final cell layout and production configuration with VTCBATT before ordering or integrating the battery.

Custom battery project support

VTCBATT offers custom battery engineering and OEM/ODM support. Share your voltage, capacity, load profile, available enclosure space, charging method, temperature range and target quantity for a project review.

Discuss the IFR32140-8S6P Battery

Get an Instant Quote
       
contact

Send Your Inquiry Now

Looking for the perfect battery solution? Our expert engineering team is ready to support you from idea to delivery. Whether you need custom voltage, size, or application-specific design, we’re here to make it happen. Get in touch today and let us power your success—one battery at a time!
Get an Instant Quote

MEET VTCBATT

Meet VTCBATT at electronica 2026.

Bring your battery project to Munich. Meet our team to explore custom lithium and wide temperature battery solutions for your next device.

WHEN
November 10–13, 2026
WHERE
Messe München · Munich, Germany
BOOTH
Hall A5 · 171/2
Plan your visit

Let’s talk batteries. Let’s build what’s next.

Scroll to Top