| Chemistry / cell configuration | LiFePO4 / IFR40135 cylindrical cells, 4S1P |
|---|---|
| Nominal voltage | 12.8V |
| Capacity / nominal energy | 20Ah / 256Wh; minimum 19.5Ah at 4A to 10V |
| Charge profile | 14.6V CC/CV; standard 4A; maximum 10A, temperature dependent |
| Continuous / peak discharge | 10A continuous; 20A for up to 5 seconds; temperature limits apply |
| Discharge cut-off | 10V |
| Charging temperature | 0 to 45°C, with current derating |
| Discharging temperature | −20 to 60°C, with current derating |
| Standard assembly dimensions | 275 × 162 × 109mm MAX; custom enclosure dimensions to be agreed |
| Standard assembly weight | 3.2kg; custom configurations may differ |
LiFePO4 Solar Street Light Battery Manufacturer in China
VTCBATT develops custom LiFePO4 battery packs for OEM equipment manufacturers. This 12.8V 20Ah platform combines cylindrical cells, battery protection and configurable outdoor installation interfaces. Explore our 12V LiFePO4 battery range when comparing energy and packaging requirements.
For solar-lighting projects, our engineering review covers the lighting programme, autonomy target, local temperatures, solar-controller settings and enclosure constraints. We can discuss battery/BMS customization, mechanical mounting, cable exits and connector matching, followed by prototype and system validation.
Built Around Outdoor Solar Lighting Requirements
Match the battery, controller and installation as a complete system.
Configure enclosure seals, cable glands and mating connectors.
Apply battery temperature sensing and specified current derating.
Match external charging control to four-series LiFePO4 cells.
Size nightly lighting programmes around verified energy capacity.
BMS protection and balancing support matched system operation.
Customize housing, mounting, cable exits and connector interfaces.
Outdoor sealing designed around the complete installation
Outdoor sealing is a configurable part of the battery assembly. For solar street lighting, review the lid seal, cable exits, fully mated connectors, strain relief and mounting exposure together. Housing and interface options can be adapted to your installation.
The product images show a custom enclosure option. VTCBATT laboratory materials illustrate water-spray testing of a different enclosure option; the final custom assembly requires its own validation. Confirm the specified IP target and applicable test report. The water-droplet illustration explains the sealing concept and does not represent a certified IP rating or immersion approval.


Temperature limits that the solar controller can enforce
Outdoor operation requires current limits based on battery temperature, rather than a single ambient-temperature headline. Charging is specified from 0 to 45°C and discharging from −20 to 60°C, with the limits below.
| Operation | Battery temperature | Maximum current |
|---|---|---|
| Charging | 0 to 10°C | 2A |
| Charging | Above 10 to 20°C | 4A |
| Charging | Above 20 to 45°C | 10A |
| Discharging | −20 to 0°C | 2A |
| Discharging | Above 0 to 10°C | 4A |
| Discharging | Above 10 to 60°C | 10A |
Place the temperature sensor where it tracks battery temperature. Inhibit charging below 0°C and outside the specified range. Stop discharge if cell surface temperature exceeds 70°C. Check solar heating inside the enclosure; the installation air temperature can be lower than the battery temperature.
A clear interface between PV charging and LED operation
Use an external MPPT solar charger matched to a four-series LiFePO4 battery. The recommended system path is PV panel → solar charge controller → battery with BMS → DC LED driver → LED engine. The controller may combine charging and lighting functions when its ratings and charge settings match the project.
Set the battery charge limit to 14.6V and cap current at 10A or the lower temperature-dependent limit. Standard charging is 4A. Coordinate load disconnect and recovery with the 10V discharge cut-off, and confirm panel voltage, connector polarity, wiring losses, surge protection and LED current before commissioning. Never connect a PV panel directly to the battery.


Size the nightly lighting profile around 256Wh
The nominal energy budget is 256Wh. Calculate demand from each programmed lighting stage, including operating hours and required nights of autonomy. Multi-stage dimming can reduce average load while preserving light when it is most useful.
Illustrative sizing: 256Wh × 80% usable depth of discharge × 90% conversion efficiency = 184.32Wh at the LED load. This supports a calculated average of 15.36W for 12 hours, or 7.68W for two 12-hour nights, before additional project reserves. These values are estimates rather than measured runtime.
Select PV power from local peak-sun-hours, seasonal shading, charging losses and the required recovery period. Higher-power street lights or longer autonomy may require a larger battery platform.
Download Specifications and Solar Lighting Guidance
Electrical limits, temperature-dependent current ratings, standard mechanical assembly and battery protection details.
Model-specific solar charging, LED control, thermal limits, illustrative energy sizing and an OEM requirements checklist.
System architecture, controller requirements, outdoor engineering and preliminary 25.6V/51.2V sizing examples. These larger-platform examples require separate sizing and do not describe this 256Wh battery.
Documentation Support and a 24-Month Model Warranty
Confirm the documentation package for your target market and the agreed terms for the IFR40135-4S1P battery.

Discuss the documentation required for your final battery configuration and target market. Confirm model-specific certification, transport-test and safety-document availability with VTCBATT. A datasheet, SDS and transport report serve different purposes; availability and scope must match the supplied assembly.

The IFR40135-4S1P model specification states a 24-month warranty from factory delivery. Confirm agreed coverage and operate within the electrical, temperature, storage and installation limits. Warranty duration is separate from cycle life and lighting autonomy.
Why Choose VTCBATT?
VTCBATT not only focuses on customized design and excellent service to meet the diverse demands of different customers, but also devotes itself to precise and standardized manufacturing in every process to ensure the highest-quality batteries. Meanwhile, VTCBATT will provide comprehensive support from pre-sales to after-sales, focusing on customers’ feedback to establish long-term and win-win cooperation. VTCBATT professional sales and technical engineer teams will be your best custom battery experts to assist with reliable and fast services at any time.
From the raw materials mixing to the cell test, VTCBATT adopts an automatic manufacturing process to maximize production efficiency and enhance the batteries quality, safety, and reliability. The entire manufacturing process is monitored and 100% tested before flowing to the next procedure to ensure zero defects before delivery.
Over the past 20 years, VTCBATT has built strong partnerships with customers in more than 50 countries worldwide. With reliable quality, responsive service, and tailored battery solutions, we have earned the trust of our clients—many of whom have maintained long-term cooperation and lasting friendships with us for over a decade. Together, we continue to grow and move forward toward a brighter future.
Match Each Lighting Scenario to Its Energy Budget
Illustrative concepts, subject to voltage/current, runtime, controller, temperature and installation checks. Higher-power lights may require a larger pack.

Potential for modest pedestrian lighting loads with programmed dimming. Match LED current and the nightly energy budget.

Consider for low-power residential access lighting after checking lamp demand, autonomy nights and seasonal PV recovery.

A candidate for individual low-power perimeter lights. Verify continuous load, timer settings and winter charge limits.

Potential storage for small solar walkway lights. Match path-lighting schedules and the available daily solar energy.

Consider off-grid lighting where the measured load fits 256Wh storage. Check rainy-season autonomy before choosing the pack.

Potential for selected campus pathway lights using a compatible external controller. Review dimming and service access.

Consider modest shelter lighting with a verified nightly load. Include every auxiliary load in the energy calculation.

Potential for low-power entrance and walkway lights. Review thermal exposure, cable protection and site requirements.
Yes. Discuss housing, mounting brackets, cable exits, lead length and connector pin assignments for the installation. Product images illustrate a custom option. The standard assembly uses a single M20 interface; confirm the agreed mechanical drawing, electrical pinout and sealing validation for the final order.
Use a compatible external solar charge controller with a four-series LiFePO4 charging profile. Set the charge-voltage limit to 14.6V and apply the temperature-dependent current limits. Match panel Voc, Vmp and Isc to the controller. The battery BMS does not provide MPPT or regulate the LED current.
The nominal energy is 12.8V × 20Ah = 256Wh. An illustrative budget using 80% usable depth of discharge and 90% conversion efficiency gives 184.32Wh at the lighting load. That corresponds to about 15.36W average for one 12-hour night, or 7.68W average for two 12-hour nights. These are calculations, not tested runtime guarantees; allow for temperature, aging and a project reserve.
Charging is specified only from 0 to 45°C. The controller must inhibit charging below 0°C and manage current according to battery temperature. A heating system or a different low-temperature design requires separate engineering confirmation.
Current is temperature dependent. Discharge is limited to 2A from −20 to 0°C, 4A above 0 to 10°C and 10A above 10 to 60°C. Charging limits are 2A from 0 to 10°C, 4A above 10 to 20°C and 10A above 20 to 45°C. Measure battery temperature inside the installed enclosure.
The BMS provides battery protection and cell balancing. A solar controller manages PV charging. A DC LED driver supplies the LED engine with the required constant current. Integrated control can be discussed for an OEM project, subject to electrical, thermal and sealing validation.
Conversion requires review of the LED forward-voltage and current range. A suitable DC LED driver normally replaces or bypasses the existing AC driver. Validate dimming, start-up, protection and thermal behavior; a 12.8V battery cannot be assumed compatible with an AC luminaire input.
The stated requirement is at least 6,000 cycles to 70% initial capacity at 25 ± 2°C with 0.5C charging and 0.5C discharging. A separate requirement is at least 2,000 cycles to 80% under 0.5C charging and 1C discharging. Laboratory cycle conditions do not override the 10A continuous pack discharge limit or guarantee field service life.
Provide the LED load and dimming schedule, nightly hours, autonomy target, installation city and seasonal temperatures, panel W/Voc/Vmp/Isc, controller details, installation space, cable and connector requirements, target ingress protection, pilot quantity and compliance requirements.
The model specification states a 24-month warranty from factory delivery. Confirm the agreed terms and operate the battery within the specified electrical, thermal, storage and installation limits.
These functions are not established as standard equipment for this model. Discuss integrated MPPT, a DC LED driver, communications or thermal accessories as separate OEM options, with confirmed interfaces, space, heat dissipation and validation requirements.
A certified IP67 rating is not established for every customization. Define the required ingress protection and request the report applicable to the final enclosure, cable entry and mating connector assembly. Laboratory water-spray footage shows test activity and does not independently prove certification or immersion suitability.
Related 12V-Class LiFePO4 Batteries
A 15Ah LiFePO4 alternative in a terminal-style enclosure. Compare its own dimensions, protection and charge settings; enclosure and interface differ from this custom solar-lighting pack.
A 40Ah LiFePO4 alternative in a terminal-style enclosure. Compare its own dimensions, protection and charge settings; enclosure and interface differ from this custom solar-lighting pack.
A 30Ah LiFePO4 alternative in a terminal-style enclosure. Compare its own dimensions, protection and charge settings; enclosure and interface differ from this custom solar-lighting pack.
A 20Ah LiFePO4 alternative in a terminal-style enclosure. Compare its own dimensions, protection and charge settings; enclosure and interface differ from this custom solar-lighting pack.
A 10Ah LiFePO4 alternative in a terminal-style enclosure. Compare its own dimensions, protection and charge settings; enclosure and interface differ from this custom solar-lighting pack.
12.8V 20Ah LiFePO4 battery engineering for solar street lighting
The IFR40135-4S1P combines four cylindrical LiFePO4 cells in series for 12.8V nominal voltage, 20Ah nominal capacity and 256Wh nominal energy. Its role in an off-grid lighting system is to store daytime solar energy and supply a compatible DC lighting circuit at night. The final system must match the battery’s voltage, current and temperature limits.
Solar charging, battery protection and LED current control
A serviceable starting architecture uses a separate battery assembly and an external solar controller. PV charging requires a compatible LiFePO4 profile and panel input ratings. The battery BMS provides overcharge, overdischarge, overcurrent and short-circuit protection together with cell balancing. A DC LED driver controls current through the LED engine. These functions may be integrated only after confirming interface, thermal, EMC, sealing and maintenance requirements.
Configure 14.6V CC/CV charging. Standard charging is 4A, with a 200mA termination condition. Maximum charge current is 10A where temperature permits. The standard discharge condition is 4A to 10V. Continuous discharge is limited to 10A, with a 20A peak for no more than five seconds. Protection thresholds are safeguards rather than normal operating targets.
BMS protection and balancing
The battery protection design specifies overcharge detection at 3.650 ± 0.050V per cell, overdischarge detection at 2.50 ± 0.100V per cell, and balancing at 3.35 ± 0.05V with 50 ± 15mA balance current. The overcurrent protection threshold is 40 ± 10A. These are protection thresholds, not normal operating ratings: the pack remains limited to 10A continuous discharge, temperature permitting. Integrate normal charging, load control and temperature logic in the matched external controller.
Temperature management for seasonal operation
| Operation | Battery temperature | Maximum current |
|---|---|---|
| Charging | 0 to 10°C | 2A |
| Charging | Above 10 to 20°C | 4A |
| Charging | Above 20 to 45°C | 10A |
| Discharging | −20 to 0°C | 2A |
| Discharging | Above 0 to 10°C | 4A |
| Discharging | Above 10 to 60°C | 10A |
Measure battery temperature inside the actual installed box. Prevent charging below 0°C and above 45°C. Enclosure temperature can rise above ambient under solar exposure. Where winter charging is required, evaluate a separately confirmed heating strategy or another battery design rather than assuming discharge capability also permits charging.
Energy sizing and autonomy
Required nominal battery energy = sum of lighting-stage watts × stage hours × autonomy nights ÷ (usable depth of discharge × conversion efficiency). Use battery-side or lamp-side power consistently so conversion losses are not counted twice.
For this 256Wh model, 80% usable depth of discharge and 90% efficiency give an illustrative 184.32Wh at the lamp. A two-night target with 12 hours each implies an average lamp load of approximately 7.68W before additional margin. The lighting programme, weather, temperature and battery aging determine real autonomy. PV power must also recover the planned energy deficit within the site’s available sunshine.
Custom housing and standard mechanical configuration
The standard assembly is specified at 275 × 162 × 109mm MAX and 3.2kg, with a 300 ± 10mm lead and M20 waterproof-style connector. These values describe the standard single-lead configuration. The ribbed enclosure and dual-cable arrangement pictured elsewhere illustrate a customizable option; agree its dimensions, pin assignment, cable routing and sealing separately.

Outdoor sealing and installation validation
Review the complete enclosure, seals, cable entry and mated connector as one system. Define the installation exposure and required ingress-protection test. Water-spray test activity does not establish certification or immersion suitability. Secure the battery against movement, provide strain relief, protect the cable and check polarity before energizing.
Cycle-life conditions and maintenance
The stated cycle-life requirement is at least 6,000 cycles to 70% initial capacity at 25 ± 2°C under 0.5C charge and 0.5C discharge. A separate test condition specifies at least 2,000 cycles to 80% at 0.5C charge and 1C discharge. These are conditional laboratory requirements; the 1C test condition does not increase the pack’s permitted 10A continuous discharge current.
For storage, specified temperature ranges are −20 to 50°C for one month, −20 to 45°C for six months, and −20 to 25°C for one year. Confirm state-of-charge and inspection guidance for the project’s storage period. Warranty is stated as 24 months from factory delivery, subject to agreed terms and operation within the specified limits.
Potential solar lighting scenarios
The following illustrations show possible low-power lighting contexts. They are application concepts rather than customer installations. Verify each complete load profile and controller before specifying the battery.




OEM project definition and pilot validation
VTCBATT can review the battery, BMS, controller interface and mechanical requirements for a solar-lighting project. Supply LED voltage/current, rated load, dimming schedule, nightly hours, rainy-night autonomy, city, seasonal temperatures, PV electrical data, available space, mounting method, connector requirements and target compliance. Confirm the configuration through bench testing, charge/discharge checks, thermal review, night simulation and a field pilot.
Discuss Your Solar Street Light Battery Requirements
Technical documents
Download the product specification PDF, solar lighting integration guide PDF and general custom solar lighting system proposal PDF. The general proposal includes higher-voltage platforms; size those separately from this 256Wh model.