INR18350HP 3.7V 1100mAh Li-ion 18350 Cylindrical Battery
| Model | INR18350HP |
|---|---|
| Cell type | Li-ion cylindrical cell |
| Nominal voltage | 3.70V |
| Typical capacity | 1100mAh at 0.2C discharge |
| Minimum capacity | 1080mAh at 0.2C discharge |
| Standard charge | CC/CV, 0.2C5A, 4.20V |
| Quick charge current | 1100mA (1.0C5 rate) |
| End-of-charge voltage | 4.20V |
| Standard discharge | CC, 0.2C5A to 2.75V |
| Quick discharge current | 11000mA (10.0C5 rate; datasheet quick-discharge rating) |
| Initial impedance | Maximum 35mΩ |
| Dimensions | Diameter Φ18.7−0.5mm (including PVC); height 35.2−0.6mm |
| Weight | Approximately 23.4±1g |
| Operating temperature | Charging: 0°C to 45°C; discharging: −20°C to 60°C |
| Storage temperature | −5°C to 35°C |
INR18350HP Key Technical Points
Compact cell format, capacity, and quick-rate data from the specification.
18.7mm diameter and 35.2mm nominal height.
1100mAh typical; 1080mAh minimum at 0.2C.
11A quick-discharge rating at 10.0C5.
Maximum initial impedance is 35 mΩ per datasheet.
Compact 18350 Cell Dimensions
The INR18350HP specification lists a diameter of Φ18.7−0.5mm including PVC and a height of 35.2−0.6mm. Check holder clearance and dimensional tolerance against the finished product design.


Quick-Rate Values for Design Review
The datasheet lists 1100mA quick-charge current at 1.0C5 and 11000mA quick-discharge current at 10.0C5. The quick-discharge value is not identified as a maximum continuous current; validate the load profile and thermal design.
Operating Temperature Ranges
Specified operating ranges are 0°C to 45°C for charging and −20°C to 60°C for discharging. The stated storage range is −5°C to 35°C. Confirm the expected temperature profile and charger limits for the target application.

Related Pack Drawing
Reference drawing for a separate 7.4V, 1100mAh 2S1P pack assembled from 18350 cells. This is not the dimensional drawing of the single INR18350HP cell above. Pack dimensions shown: 36.5 mm max x 37.5 mm max; 20.0 mm max across the cell layout; lead length 30 +/- 3 mm.
Cell Specifications for Product Selection
Review the source ratings and verify suitability in the target device.

Single-cell dimensions are specified as Φ18.7−0.5mm diameter including PVC and 35.2−0.6mm height.

1100mAh typical and 1080mAh minimum at 0.2C; quick discharge is listed at 11A.

Charging: 0°C to 45°C. Discharging: −20°C to 60°C, per the datasheet.
Why Choose VTCBATT?
VTCBATT works with customers on customized battery design and responsive project support. Sales and technical teams help clarify product requirements and coordinate suitable battery solutions for different applications.
VTCBATT coordinates manufacturing and product checks across its battery production process, with technical support available to discuss requirements for a specific project.
VTCBATT provides sales and technical support for customers developing battery products, from requirement discussions through project follow-up.
Where an 18350 Cell May Fit
These are possible application contexts, not confirmed customer uses. Confirm electrical, thermal, runtime, charger, protection, and installation requirements for each design.

Consider for compact test meters only when the cell holder, voltage range, peak current, runtime, and charger match the equipment design.

A possible fit for compact audio equipment after checking its current draw, recording runtime, charging method, and temperature conditions.

Evaluate for low-power monitoring equipment by verifying transmission peaks, standby runtime, charging access, and environmental exposure.

Check the flashlight’s voltage, peak and continuous current, heat dissipation, runtime target, and charging design before selection.

Potentially suitable where an 18350 holder and load profile meet the instrument’s power, runtime, charging, and temperature requirements.

Verify device voltage, scan duty cycle, radio transmission peaks, expected runtime, protection, and charger compatibility.

Assess only after checking startup peaks, motor or actuator loads, thermal limits, cell protection, runtime, and mechanical retention.

Confirm receiver voltage, display and positioning runtime, peak load, charging approach, and operating temperature before use.
The datasheet lists a typical capacity of 1100mAh and a minimum capacity of 1080mAh at 0.2C discharge.
The specified end-of-charge voltage is 4.20V. The standard charging method is CC/CV at 0.2C5A. Use a charger designed for the cell’s specified limits.
The specification gives a diameter of Φ18.7−0.5mm including PVC and a height of 35.2−0.6mm. Confirm holder clearance and production tolerances for the intended design.
The specification lists 11000mA (10.0C5 rate) as quick-discharge current. It does not label this value as a maximum continuous discharge current; validate the intended current profile and thermal conditions with the supplier.
No. It describes a separate 7.4V INR18350-2S1P pack. The page labels that drawing as a reference pack configuration so it is not confused with the INR18350HP single-cell dimensions.
INR18350HP 3.7V 1100mAh Cell Overview
The VTCBATT INR18350HP is a rechargeable Li-ion cylindrical cell in the 18350 size class. Its specification lists a 3.70V nominal voltage, 1100mAh typical capacity, and 1080mAh minimum capacity, with capacity measured at a 0.2C discharge rate.
Charging and Discharging Ratings
Standard charging is specified as CC/CV at 0.2C5A with a 4.20V end-of-charge voltage. The listed quick-charge current is 1100mA (1.0C5 rate). Standard discharge is constant current at 0.2C5A to a 2.75V end-of-discharge voltage. The datasheet also lists a quick-discharge current of 11000mA (10.0C5 rate). This quick-discharge figure is not identified as a maximum continuous current, so the final design should account for current profile, temperature rise, protection, and duty cycle.
Dimensions, Weight, and Temperature
The initial dimensions are specified as Φ18.7−0.5mm diameter including PVC and 35.2−0.6mm height. Approximate weight is 23.4±1g. The stated charging temperature range is 0°C to 45°C, the discharging range is −20°C to 60°C, and the storage range is −5°C to 35°C. Confirm space, ventilation, thermal conditions, charger compatibility, protection, and applicable transport and product requirements for the finished equipment.
Cycle-Life Test Condition
The datasheet reports at least 300 cycles under its stated test: constant-current 1.0C charging to 4.2V, constant-voltage charging until current falls to 0.01C, a 10-minute rest, then 10.0C discharge to 3.0V and a 30-minute rest. The test is repeated until discharge capacity falls below 80% of initial capacity. This result is tied to that test procedure and should not be treated as a guaranteed service life in every device or operating condition.
Use the Pack Drawing Correctly
The included VTC INR18350-2S1P drawing describes a separate 7.4V, 1100mAh two-cell pack. Its maximum dimensions and wire details apply to that pack assembly, not to one INR18350HP cell. Use the cell’s own specification dimensions for single-cell mechanical design.
Potential application fit depends on the device’s voltage, current demand, runtime target, charging system, temperature, protection, and installation. Confirm these requirements with the engineering team before specifying the cell.