Low temperatures can increase cell impedance, reduce usable capacity and cause voltage sag under load. VTCBATT develops custom low-temperature LiPo batteries for equipment that must discharge in cold environments. Selected models are designed for discharge down to -40°C; actual output depends on the cell, load and device cutoff voltage.
Pack dimensions, capacity, discharge capability and protection design can be tailored to the device. Share the operating temperature, load profile and cutoff voltage for a model-specific review and validation plan.
Low-Temperature LiPo Battery Models
Compare available models and confirm the exact datasheet, temperature limits and test conditions before selection.
Model: VTC-LP603450T · 3.7V / 1000mAh
Max size (T × W × L): 6.2 × 34.5 × 52mm
Discharge: −40°C to 60°C
Model: VTC-LP104040T · 3.7V / 2000mAh
Max size (T × W × L): 10.2 × 40.5 × 42mm
Discharge: −40°C to 60°C
Model: VTC-LP703958 · 3.7V / 2100mAh
Max size (T × W × L): 7.2 × 39.5 × 60mm
Discharge: −40°C to 60°C
Model: VTC-LP554654 · 3.7V / 1500mAh
Nominal model-code size (T × W × L): 5.5 × 46 × 54mm
Discharge: −40°C to 60°C
Model: VTC-LP695168LT · 3.7V / 3000mAh
Max size (T × W × L): 6.9 × 51 × 68mm
Discharge: −40°C to 60°C
Model: VTC-LP715868LT · 3.7V / 3500mAh
Max size (T × W × L): 7.1 × 58 × 68mm
Discharge: −40°C to 60°C
Model: VTC-LP103048LT · 3.7V / 1400mAh
Max finished-pack size (H × W × T): 50.0 × 30.5 × 10.2mm
Discharge: −30°C to 60°C
Standard LiPo vs. Low-Temperature LiPo
| Parameter | Standard LiPo Cell | Low-Temperature LiPo Cell |
|---|---|---|
| Discharge operating range | Typically -10°C to 60°C; confirm the cell specification. | Typically -40°C to 60°C for rated models; confirm the model. |
| Capacity retention at -20°C | Indicative 20%–40% for some cells under defined conditions; load and cutoff voltage affect results. | Indicative 80%–85%+ for selected cells under defined conditions; verify model and test rate. |
| Discharge at -40°C | May not support the required load; usable capacity depends on current and cutoff voltage. | Selected models may retain roughly 50%–70% under specified conditions. Confirm rate, soak time and cutoff voltage. |
| Electrolyte system | Conventional formulation; low-temperature ion transport can become limited. | May use low-freezing-point co-solvents and functional additives; formulation varies by manufacturer. |
| Impedance / internal resistance | Resistance and voltage sag generally increase in the cold, potentially causing early device cutoff. | Cold-focused designs aim to limit impedance rise; confirm with low-temperature discharge curves. |
| Sub-zero charging | Do not charge below the cell’s specified minimum; cold charging can increase lithium-plating risk. | Only selected models support sub-zero charging, often at restricted rates; follow the exact cell and charger limits. |
| Specific energy and cost at 25°C | Indicative 200–260 Wh/kg; baseline pricing varies by supplier and specification. | Indicative 160–220 Wh/kg. A 5%–15% density trade-off and 50%–100% price premium may apply in some comparisons; figures are model- and quote-specific. |
Low-Temperature LiPo Battery Sourcing Guide
Confirm these details against the exact cell and pack configuration before approving samples or production.

Confirm minimum and maximum discharge temperatures, charging limits, and recommended storage temperature, state of charge and duration.

Specify nominal voltage, usable capacity or runtime, continuous current, peak or pulse current with duration and repetition rate, and device cutoff voltage.

Request discharge curves or test data at target temperatures, including load or C-rate, soak time, starting state of charge, cutoff voltage, sample count, capacity and voltage results.

Confirm whether the exact model supports sub-zero charging, permitted temperature and rate, NTC location and specification, charge cutoff and restart criteria, and charger/BMS coordination.

Confirm cell and pack dimensions with tolerances, mass, swelling allowance and compression limits, connector, wire gauge and length, polarity/pinout, and protection circuit or BMS details.

Review the UN 38.3 test summary for transport, applicable product safety and market conformity documents, batch traceability and consistency controls, and PCN/EOL notification process.

Confirm sample cost and lead time, production MOQ and lead time, annual capacity allocation, quote validity, and forecast-based volume pricing.
Applications for Low-Temperature LiPo Batteries
Select and validate a pack against the complete device load, operating temperature and cutoff voltage.
Remote trackers may sleep for months before short GNSS, cellular or satellite transmission bursts. Match the pack to pulse demand, reporting schedule and cutoff voltage to reduce missed check-ins and resets.

Cold-chain loggers and industrial monitors can operate in deep-freeze storage, refrigerated freight and harsh environments. Validate sampling, transmission schedule, service interval and system cutoff at the target temperature.

Propulsion, image processing and radio transmission create continuous and peak loads in cold-weather UAVs, thermal cameras and field computers. Match pulse duration, cutoff voltage and runtime, then validate the full device at the intended temperature.

Portable monitors, defibrillators and infusion pumps may face cold starts and required runtime in unheated vehicles or outdoor rescue. Specify startup load, telemetry, cutoff voltage and duty cycle, and confirm the exact pack’s temperature rating.
LOW-TEMPERATURE CUSTOM PACKS
Custom Low-Temperature LiPo Pack Configuration
Configure a LiPo pack around your device’s operating temperature, runtime and installation space. Selected low-temperature models are designed for discharge down to -40°C; confirm the exact cell, load and device cutoff voltage against model-specific data.
- Cell format, capacity and discharge profile for the target temperature
- Pack dimensions, tabs and leads, connector and protection design
- Validation with cold soak, operating load and device cutoff voltage
Low-Temperature Discharge Test Results
GRP703958 · 2,100mAh · Report dated January 25, 2024. Cells were charged to 4.2V at 25±2°C with a 0.01C cutoff, cooled to the test temperature within 30 minutes, soaked for 3 hours and discharged to 2.75V.
| Test temperature | Rate | Sample 1 | Sample 2 | Sample 3 | Average / 25°C reference |
|---|---|---|---|---|---|
| 25°C reference | 0.5C | 2,245mAh | 2,202mAh | 2,312mAh | 2,253mAh (100%) |
| -40°C | 0.2C | 1,722mAh | 1,762mAh | 1,730mAh | 1,738mAh (77.2%) |
| -40°C | 0.5C | 1,174mAh | 1,235mAh | 1,190mAh | 1,200mAh (53.3%) |
The 77.2% value compares -40°C at 0.2C with the 25°C reference at 0.5C, so it is a cross-rate ratio. The 53.3% value compares both results at 0.5C. The report states that -40°C at 0.5C was for reference only, not a required pass criterion. After each temperature test, the cells were returned to 25±5°C for 2 hours before recharging. Results apply to the tested samples and setup.
A low-temperature LiPo battery is a lithium-ion polymer pouch cell designed to deliver usable power in cold environments. Some models are rated for discharge down to -40°C; lower limits should be stated only when validated for a specific cell or pack. Charge, discharge and storage limits vary by model. Depending on the design, low-temperature cells may use electrolyte, electrode or interface modifications to improve cold-weather performance. Check the datasheet for temperature limits, capacity and test conditions.
It can if the specific cell is rated for that temperature. Actual performance depends on the model, load profile, state of charge and cutoff voltage. Low-temperature discharge capability does not establish a charging rating.
A low-temperature discharge rating does not mean the cell can be charged below freezing. Charging below the specified minimum can promote lithium plating and create safety risks. Some specially designed cells support sub-zero charging; follow the exact cell and pack limits, permitted rate and temperature controls.
Low temperatures slow electrochemical processes and can increase cell impedance. Voltage sag under load may bring the battery to the device’s low-voltage cutoff before all nominal capacity is delivered. The effect depends on temperature, state of charge, current demand and cutoff voltage.
- Operating temperatures for discharge, charging and storage, including whether sub-zero charging is required.
- Nominal voltage, capacity or runtime, continuous and peak current, pulse duration and device cutoff voltage.
- Maximum dimensions, weight, connector, wire length, polarity and pinout.
- Charging method, charge rate, PCM/BMS requirements and temperature-sensor needs.
VTCBATT’s in-house lab can conduct battery tests using environmental chambers and charge/discharge equipment across a configured range of -50°C to +70°C. The team can review an agreed test profile, including temperature, current or pulse load, soak time and cutoff voltage. Confirm the test scope and setup with the engineering team; results apply to the tested sample and configuration.